Tuesday, March 11, 2008

Message To Write In A Book For A Baby

DESCRIPTIVE MEMORY

Specially designed to fulfill the mission of Gateway National Bank Vault resistant to fire, drilling holes, cutting tools, acetylene torches, flood and explosives, for which and through different shields that are detailed, is achieved in solid door to a maximum of 158 mm. distributed as follows:
carbon steel plate 10 mm. thick.
manganese steel plate of 4 mm. thick.
anti-torch Material over 20 mm. thick.
manganese steel plate of 4 mm. thick.
refractory monolithic block of 120 mm. thickness.
Next of this solid is the shielding mechanism consisting of:
copper plate of 6 mm. thick.
Mn steel plate. 4 mm.
thick carbon steel plate of 5 mm. thick.
On the last sheet is prepared for fastening mechanisms that are being placed with a total thickness of door, including 250-mm buttress.
The door rests on metal frame with refractory block of 450 mm.
seals upper and lower side of the door is effected by means of sheet steel of 2 mm. thick welded properly folded folder.
To adjust the door frames, are arranged with their corresponding double plug sockets in a trap, which prevents the use of tools of rape and the passage of gases or fumes to the interior, in case of fire, explosion. etc.





the perfect setting for the door, into the socket outlet is housed a copper seal 20x4 mm. and the trap snaps of other special 30x10 rubber gasket to make the tight compression against flooding. This system consists of a three-spoke steering wheel exterior with spindle drive wide, that acts on two wheels 40x20 mm. housed inside the door at the height of the latches and acts notches housed on the door frame and pushing against it, adjusted to allow for the subsequent entry of the locking latches. This movement is helped turn poe double hinges.
hinges or seat, dual-axis, consist of fixed parts welded to the door and forged steel construction frame of 60 mm. and the moving part consists of a single element fojado 60x100mm steel construction. and joined by U of 160 mm. all welded properly. top hinges are fitted with radial needle bearings and ball bearing lower resistance being calculated to withstand more than twice the weight of the door.
The closure is effected by means 6-calibrated steel bolts of 50 mm., placed on the left side and 3 on the right of the door being operated simultaneously by the drive gear to handle.
the two combinations
SANGERT & GREENLEAF 4 disc five positions with the hidden plate numbered spies or-100, allowing up to 100,000,000 different combinations, closed by conviction. You are combination locks are approved by Underwriters Laboratories, Inc. of USA and may be used one or other or both interchangeably. Connecting the two locks, anti-explosive iran two mechanisms of these elements of security. Mechanisms are in the inside of the door through a strong anti acro is joined by hinges forged steel lock convicted.
door gate. is constructed by a rectangular frame with 20 mm bars. spaced 60 mm diameter. on the right side will be a blind spot to hide the two different locks to be opened from the outside and inside and turn on hinges welded to frame properly.
finish. All exterior door and frame will be lined by stainless steel.

DOOR OUTSIDE DIMENSIONS TREASURY LAUNCHES ANTI-HIGH HEAT

2,200 mm. WIDTH 1,250 mm. FUND 450 mm.

WEIGHT 5,500 kg. 1.-Steel

LD. 10 mm.

2.-Manganese Steel 4 mm. 3.-Shield

MAS 20 mm anti-torch. 4.-Mass

refractory

120 mm.

5.-6 mm copper plate. 6.-Steel

LD fastening mechanisms

7.-locking latches 6 50 mm diameter.

8.-lock anti-explosive combination.

9.-Compression System

hermetic door gate

10.-11.-Deck

20x4 mm copper.

12.-hermetic Board 30x10 mm.

double acting hinge 13.-14.-Wheel

watertight seal

15.-button combination locks

16.-handle latches drive

very

Party important in building armored doors are locks. I'll

Accountant told me a story that a British company manufacturing safes that make the world better armored doors for national banks.
The place of honor is occupied by the MOSSAD their thieves of safes and locks experts. Have the ability to break into sealed areas is legendary, and his ability to pair the burglary was considered the best.
So high is the reputation of the Mossad locksmiths when British manufacturers sent a new product to the SIS for that comment, I went to Tel Aviv. The Mossad was studying him, I discovered how to open and returned to London under the label of impregnable. The SIS found that proceeding.
The next time a British company had a lock locksmith particularly safe. The SIS asked them to provide a more easy. The latter was the one sent to Tel Aviv. They studied it and opened it, and then returned to London saying that it was impossible to open. The SIS advised the manufacturer that marketed good lock.
This led to an embarrassing incident a year later when a locksmith Mossad spent three hours sweating to open this lock in the corridor of an office of a European capital, before leaving livid with rage. Since then the British test their own locks.


0 comments:

Post a Comment